An OASIS edit is a rule iQIES checks every record against. Break a fatal edit and the record is rejected until you fix it and send it again. Break a warning edit and the record is accepted, but the warning stays on your validation report. Below are 15 edits, what each one checks in plain words, and how to fix it, using CMS's own text. Each number links to its page in our free OASIS edit lookup.
Sources: CMS's OASIS-E2 Data Submission Specifications V3.02.0, the current version on CMS's Data Specifications page (opens in a new tab) as of November 16, 2026, and the iQIES OASIS Error Message Reference Guide v2.4 (posted February 5, 2026 on the QTSO reference manuals page (opens in a new tab)). We checked our lookup's text for all 15 edits against both files on November 16, 2026.
The 15 Edits
These are 15 iQIES fatal errors and warnings from CMS's OASIS-E2 data specifications. The sections below give what triggers each one and how to fix it.
| Edit | Severity | What it checks |
|---|---|---|
| -3330 | Warning | New record submitted more than 30 days after M0090 |
| -4410 | Fatal | M1740 "none of the above" checked with a behavior also checked |
| -3480 | Fatal | M0018 NPI "unknown" checked, but an NPI entered |
| -4400 | Fatal | M1740 has nothing checked at all |
| -7061 | Fatal | D0160 depression score does not match the D0150 answers |
| -3320 | Warning | Discharge assessment not completed 0 to 2 days after M0906 |
| -3200 | Fatal | Correction number is not the last one plus 1 |
| -3450 | Fatal | M1005 date blank, but "unknown" not checked |
| -4850 | Fatal | Medicare fee-for-service in M0150, but no Medicare number in M0063 |
| -7050 | Fatal | A correction does not match any accepted record |
| -3060 | Fatal | A value that is not allowed for the item |
| -4320 | Fatal | M1600 answered "UK" on a discharge |
| -5070 | Fatal | Flu season period, but M1046 left blank |
| -5290 | Fatal | Transfer, death or discharge with no M0906 date |
| -4570 | Fatal | Discharge with an inpatient facility in M2410 |
Fatal or Warning: What Happens to the Record
CMS's data specifications define the two:
- Fatal: "Violation of a fatal edit will result in rejection of the submission file. Format and skip pattern edits are always fatal. Most consistency edits are fatal, but some are warnings."
- Warning: "a warning will not prevent the submitted assessment data from being accepted and stored in the iQIES system."
iQIES posts a Final Validation Report "within 24 hours of successful submission of a file." It lists each error by number and severity, with "the submitted item values that triggered the error." CMS's guide says: "All fatal errors in a record must be corrected and resubmitted," and "All warning errors should be reviewed and corrected if appropriate."
A rejected record is not in iQIES until a corrected copy is accepted.
Timing Warnings
-3330: Record submitted late (warning)
What triggers it: a new record (transaction type 1) reaches iQIES more than 30 days after M0090, the date the assessment was completed. CMS's message: "Record Submitted Late: The submission date is more than 30 days after M0090 on this new record."
How to fix it: the record is accepted. CMS's guide gives its usual action, "Make appropriate corrections to the records and resubmit," and asks you to correct warnings "if appropriate." If M0090 is the real completion date, nothing in the record is wrong; it was sent late. The fix is to send records sooner. 42 CFR 484.45(a) requires each completed assessment to be transmitted "within 30 days of completing the assessment of the patient." Find where records wait: QA review, a clinician's late sign-off, or a batch that goes out once a month.
-3320: Discharge assessment outside the 2-day window (warning)
What triggers it: on a discharge (M0100 = 09), M0090 minus M0906 (the discharge date) is less than 0 or more than 2 days. CMS's message: "If M0100 is equal to 09, then M0090 minus M0906 should be greater than or equal to zero and less than or equal to 2 days."
How to fix it: check both dates against the visit note. If both are right, the discharge assessment was completed late, and the record is accepted with the warning. If one was keyed wrong, see -7050 below first: M0090 and M0906 are both items iQIES uses to find the original record, so a modification that changes them will not match. CMS's guidance manual says a record with a wrong key field "must be inactivated, and a new replacement record should be submitted," and points to QTSO for the list of key fields.
Corrections That Fail
-3200: Wrong correction number (fatal)
What triggers it: every modification or inactivation carries a correction number, CORRECTION_NUM. CMS's rule: the first correction to a record "must be '01'," and each later one "must be incremented by 1." If it is anything else, the correction is rejected.
How to fix it: look up the last accepted correction for that record and add 1. CMS's tip: "The value of CORRECTION_NUM minus 1 must equal the value of CORRECTION_NUM that was previously submitted successfully for this record." A rejected correction does not count, so a resend after a rejection keeps the same number.
-7050: No matching record found (fatal)
What triggers it: iQIES cannot find the record you are trying to modify or inactivate. To find it, iQIES matches 12 items against the accepted record: M0030 (start of care date), M0032 (resumption of care date, and its "NA" box), M0040 first and last name, M0064 (Social Security number, and its "unknown" box), M0066 (birth date), A0810 (sex), M0090 (date assessment completed), M0100 (reason for assessment) and M0906 (discharge, transfer or death date). CMS's message: "No Match Found: This modification/ inactivation record does not match a previously accepted record in the iQIES System."
How to fix it: copy those 12 values exactly as they are in the accepted record, even if one of them is the thing that is wrong. Check spelling of names, transposed digits and dates. This edit is new with OASIS-E2 and replaces -3190. Both lists have 12 items; the new one has A0810 (sex) where the old one had M0069 (gender).
Checkbox and "Unknown" Pairs
-4410: M1740 "none of the above" with a behavior checked (fatal)
What triggers it: M1740-7, none of the above, is checked, and one or more of M1740-1 to -6 (memory deficit, impaired decision-making, verbal disruption, physical aggression, socially inappropriate behavior, delusions) is also checked. CMS's message: "If M1740-7 is equal to 1, then all items M1740-1 through M1740-6 must equal 0."
How to fix it: decide which is true and uncheck the other. On the validation report, CMS notes, "A checked response displays as a '1'" and "An unchecked response displays as a '0'."
-4400: M1740 with nothing checked (fatal)
What triggers it: the reverse of -4410. M1740-7 is unchecked and none of M1740-1 to -6 is checked either. CMS's message: "If M1740-7 is equal to 0, then at least one item M1740-1 through M1740-6 must equal 1."
How to fix it: check the behaviors the clinician saw, or check 7, none of the above.
-3480: NPI "unknown" with an NPI entered (fatal)
What triggers it: M0018-UK, attending physician NPI unknown, is checked, but an NPI is also entered. CMS's message: "If M0018-UK is equal to 1, then M0018 NPI number must equal blank (^)."
How to fix it: if you have the NPI, keep it and uncheck UK. If you do not, leave the NPI blank. Our M0018 item page has the item text.
-3450: Inpatient discharge date missing (fatal)
What triggers it: M1005-UK, inpatient discharge date unknown, is unchecked, but the date is blank. CMS's message: "If M1005-UK is equal to 0, then M1005 date must not equal blank (^)."
How to fix it: enter the most recent inpatient discharge date, or check UK if the date is unknown. See the M1005 item page.
-4850: Medicare fee-for-service with no Medicare number (fatal)
What triggers it: M0150-1, Medicare (traditional fee-for-service), is checked as a payment source, but M0063, the Medicare number, is blank. CMS's message: "If M0150-1 is equal to 1, then M0063 Medicare Number must not equal blank (^)."
How to fix it: enter the patient's Medicare number in M0063. If the patient's Medicare comes through an HMO or managed care plan, M0150 has a separate response for that (Medicare HMO/managed care), so check that M0150-1 is the right box. See M0150 and M0063.
Discharge Assessment Items
-5290: Transfer, death or discharge with no date (fatal)
What triggers it: the reason for assessment is a transfer (06 or 07), death at home (08) or discharge (09), but M0906 is blank. CMS's message: "If M0100 is equal to 06, 07, 08, or 09, then M0906 must not equal blank (^)."
How to fix it: enter the discharge, transfer or death date in M0906.
-4320: M1600 answered "UK" on a discharge (fatal)
What triggers it: on a discharge (M0100 = 09), M1600, treated for a urinary tract infection in the past 14 days, is answered UK (unknown). CMS's message: "If M0100 is equal to 09, then M1600 must not equal UK."
How to fix it: answer 00 (no), 01 (yes) or NA (patient on prophylactic treatment). UK is not allowed at discharge. See the M1600 item page.
-4570: Discharge with an inpatient facility in M2410 (fatal)
What triggers it: on a discharge (M0100 = 09), M2410, inpatient facility, is anything other than NA ("No inpatient facility admission"). CMS's message: "If M0100 is equal to 09, then M2410 must equal NA."
How to fix it: if the patient was not admitted anywhere, answer NA. If the patient did go to one of the M2410 choices (hospital, rehabilitation facility, nursing home or hospice), the assessment may have needed a transfer reason (06 or 07) rather than discharge (09). M0100 is one of the items iQIES uses to find a record (see -7050), so a modification that changes it will not match the original. The RFA codes chapter of our OASIS manual covers which reason fits.
-5070: Flu season, M1046 left blank (fatal)
What triggers it: M1041 is answered 1 (yes), meaning the episode of care includes a day from October 1 through March 31, but M1046, influenza vaccine received, is blank. CMS's message: "If M1041 is equal to 1, then M1046 must not equal blank (^)." This is a skip pattern edit, so it is always fatal.
How to fix it: answer M1046 with one of its codes, 01 to 08. It only comes up on records whose episode includes a day from October through March.
The Depression Score
-7061: D0160 does not match the D0150 answers (fatal)
What triggers it: D0160, the total severity score, is not the number CMS's rules give from the D0150 mood interview (the PHQ). This edit is new with OASIS-E2 and replaces -5910. CMS's rules, in order:
- If D0150A1 and D0150B1 (the first two symptom questions) are both 9, no response, D0160 must be blank.
- If D0150A2 and D0150B2 (how often for those two) are both 0 or 1 (never to 6 days), D0160 is their sum.
- Otherwise the full nine questions are asked, and D0160 is the sum of D0150A2 through D0150I2.
- If one of those nine is a dash or skipped, D0160 is the sum of the rest times 9/8, rounded to the nearest whole number.
- If two are missing, the sum of the rest times 9/7, rounded.
- If three or more are missing, D0160 must be 99 (unable to complete interview).
How to fix it: recalculate D0160 by these rules. If your software calculates the score, look for a score keyed by hand or a frequency answer changed after the score was set. One caution: CMS's error guide tip for this edit's sixth rule describes a 9/6 calculation, but its own error message and the data specification both say 99. Follow the specification.
Format
-3060: Value not allowed for the item (fatal)
What triggers it: a value that is not in the item's list of allowed codes. It applies to 365 items. CMS's message: "Invalid Value: The value submitted for this item is not an acceptable value."
How to fix it: the validation report shows the item and the value. Compare it with the item's allowed values in the data specifications, fix the value, and resubmit. With OASIS-E2, CMS removed this edit's checks for the deleted items A1250, M0069 and O0350 and added them for the new items A0810 and A1255. If your software wrote the value, ask your vendor.
Before 2027
From 2027, agencies have less time to fix fatal errors. CMS's final rule moves the OASIS submission and correction deadline to the 15th day of the second month after each quarter. The first is May 17, 2027, for January to March. Details in the OASIS submission deadline is moving. Read your validation report the day after each file goes in, not at the end of the quarter.
Related on This Site
- OASIS edit lookup: every V3.02.0 edit, with CMS's text and the error guide's entries.
- OASIS QA and corrections: when to modify and when to inactivate.
- Submitting OASIS to iQIES: files, the validation report and rejections.
- Legacy iQIES data entry ends December 31, 2026.
Frequently Asked Questions
What is an OASIS edit code?
It is the number of a rule in CMS's OASIS data submission specifications, such as -4410. iQIES checks every record you submit against these rules. When a record breaks one, the validation report lists the edit's number, whether it is fatal or a warning, and the item values that triggered it.
What is the difference between a fatal error and a warning in iQIES?
A fatal error rejects the record. CMS says all fatal errors in a record must be corrected and the record resubmitted. A warning does not stop the record from being accepted and stored in iQIES, but CMS says every warning should be reviewed and corrected if appropriate.
What does OASIS edit -3330 mean?
It is a warning that a new record reached iQIES more than 30 days after its M0090 date, the date the assessment was completed. The record is still accepted. If M0090 is right, the record is simply late, and the fix is getting assessments out within 30 days, which 42 CFR 484.45(a) requires.
Why does iQIES reject my M1740 answers?
Two fatal edits check M1740. If response 7, none of the above, is checked, edit -4410 requires responses 1 through 6 to be unchecked. If response 7 is unchecked, edit -4400 requires at least one of responses 1 through 6 to be checked. Mark either the behaviors you saw or none of the above, not both and not neither.
Sources
- CMS, OASIS Data Specifications (opens in a new tab): OASIS-E2 Data Submission Specifications V3.02.0 FINAL (zip (opens in a new tab)), the edit pages for each edit above, and the Data Submission Specifications Overview V3.02.0 (section 6.4, severity). Read November 16, 2026.
- CMS / QTSO, iQIES OASIS Error Message Reference Guide v2.4, Excel and PDF, February 5, 2026, on the QTSO reference manuals page (opens in a new tab). Read November 16, 2026.
- CMS, OASIS-E2 Guidance Manual, effective April 1, 2026, Chapter 2, section 2.4 (modification and inactivation), on the OASIS User Manuals page (opens in a new tab).
- 42 CFR 484.45 (opens in a new tab), reporting OASIS information. Read November 16, 2026.
- CMS, CY 2027 home health final rule (CMS-1844-F), public-inspection PDF (opens in a new tab), Table 19, p. 137.
Keep the visits behind each assessment on time
Logicly works out each patient's cert periods and recert window from the start of care, places the week's visits from their frequencies and puts each day in driving order.