October 1 update. Our PDGM and ICD-10 tools now use the FY2027 code set: 190 codes added, 30 deleted, and no existing code changed clinical group.

See what changed
Lifetime rate: $24/mo

OASIS edit -3290: Inconsistent Dates

Edit -3290 is a warning consistency edit in CMS's OASIS-E2 data specifications V3.02.0, effective for records with completion dates on or after 2026-04-01. iQIES reports it as "Inconsistent Dates". A warning does not block the record: CMS's overview says a warning "will not prevent the submitted assessment data from being accepted and stored in the iQIES system." The iQIES error guide adds: "All warning errors should be reviewed and corrected if appropriate, to ensure the data uploaded is accurate and complete." It checks 3 items: M0032_ROC_DT, M0100_ASSMT_REASON, M1005_INP_DISCHARGE_DT. CMS's action: "Make appropriate corrections to the records and resubmit."

What CMS's data specification says about -3290

CMS's OASIS-E2 Data Submission Specifications V3.02.0 (HTML edit page oe_3290.html, generated 11/05/2025) list edit -3290 with edit type Consistency and severity Warning. The edit text, as CMS publishes it:

If M0100_ASSMT_REASON=[03] and if M0032_ROC_DT and M1005_INP_DISCHARGE_DT are both active and contain valid dates (not [^]), then M0032_ROC_DT minus M1005_INP_DISCHARGE_DT should be greater than or equal to zero and less than or equal to 14.

CMS's overview document defines this edit type: "Consistency edits define logical constraints among multiple items."

What the iQIES error message for -3290 says

CMS's OASIS Error Message Reference Guide v2.4 (Excel, posted 2026-02-05 on the QTSO reference manuals page) has 1 current entry for this edit. Each is copied in full, with whitespace normalised:

-3290

Error ID
-3290
Severity
Warning
Type
Consistency
Error message
Inconsistent Dates: If M0100 is equal to 03, then M0032 minus M1005 should be greater than or equal to zero and less than or equal to 14 days.
Potential cause
The assessment was not completed within CMS timing guidelines.
Tips
IF M0100 (Reason for Assessment) is 03 and M0032 (Resumption of Care Date) and M1005 (Inpatient Discharge Date) are both active and are not blank (^), THEN M0032 minus M1005 should be greater than or equal to zero but no more than 14 calendar days.• M1005 should only be entered when the patient was discharged from an inpatient facility within the past 14 days prior to admission to a home health agency.
Action
Make appropriate corrections to the records and resubmit.
Effective start date
2010-01-01
Effective end date
2099-12-31 (CMS uses this date for an open-ended entry)

Items this edit checks

CMS's Item List for -3290 names 3 items.

Item IDDescription (CMS)Item page
M0032_ROC_DTResumption of care dateM0032
M0100_ASSMT_REASONReason for assessmentM0100
M1005_INP_DISCHARGE_DTMost recent inpatient discharge dateM1005

Other current edits whose CMS Item List shares one or more items with -3290 (the broad -3060 value edit, which covers 365 items, is left out):

Edit IDSeverityTypeiQIES labelItems shared
-3070FatalFormatInvalid Date2
-3261FatalConsistencyInconsistent Dates2
-3271FatalConsistencyInconsistent Dates2
-3280WarningConsistencyInconsistent Dates2
-3310WarningConsistencyInconsistent Dates2
-5350FatalConsistencyInconsistent Dates2
-7050FatalConsistencyNo Match Found2
-3300WarningConsistencyInconsistent Dates1

What happens to the record

CMS's overview, section 6.4, on warning edits: "Violation of a warning edit will result in a warning message on the user feedback report. However, a warning will not prevent the submitted assessment data from being accepted and stored in the iQIES system." CMS's iQIES error message guide: "All warning errors should be reviewed and corrected if appropriate, to ensure the data uploaded is accurate and complete."

Which records this edit applies to

Data specifications version 3.02 has an effective start date of 2026-04-01 and no end date (CMS overview, Table 1). CMS selects the edit set by the record's completion date: "When a submitted record is validated by the iQIES system, its completion date is evaluated and is used to load the appropriate set of edits for the specifications in effect on that date."

Frequently asked questions

Is OASIS edit -3290 fatal or a warning?

A warning. CMS lists edit -3290 with severity Warning in the OASIS-E2 data specifications V3.02.0. The CMS overview states: "Violation of a warning edit will result in a warning message on the user feedback report. However, a warning will not prevent the submitted assessment data from being accepted and stored in the iQIES system."

Which OASIS items can trigger edit -3290?

CMS's Item List for edit -3290 names 3 items: M0032_ROC_DT, M0100_ASSMT_REASON, M1005_INP_DISCHARGE_DT. The full list with descriptions is in the table above.

How do I fix OASIS edit -3290?

CMS's OASIS Error Message Reference Guide v2.4 gives this action for -3290: "Make appropriate corrections to the records and resubmit." Its tips are quoted in full above.

Which records does edit -3290 apply to?

Under version 3.02 of the data specifications, records whose completion date, item M0090_INFO_COMPLETED_DT, is on or after 2026-04-01, the effective start date CMS gives that version. Records completed earlier are checked under the version in effect on their completion date (CMS overview, Table 1 and section 3.2); the effective start date on each guide entry above is the date CMS's error guide gives that entry. The CMS overview states: "When a submitted record is validated by the iQIES system, its completion date is evaluated and is used to load the appropriate set of edits for the specifications in effect on that date."

Sources

  1. CMS, OASIS-E2 Data Submission Specifications V3.02.0 FINAL (zip): HTML edit page oe_3290.html and the Unduplicated Edits By ID Report. https://www.cms.gov/files/zip/oasis-e2-data-specs-v3-02-0-final-zip.zip (download page: https://www.cms.gov/medicare/quality/home-health/data-specifications)
  2. CMS, OASIS Data Submission Specifications Overview, Version 3.02.0, October 29, 2025 (in the same zip).
  3. CMS QTSO, OASIS Error Message Reference Guide v2.4 (Excel), posted 2026-02-05. https://qtso.cms.gov/system/files/qtso/OASIS%20Error%20Message%20Reference%20Guide%20FINAL%202.4.26.xlsx

CMS text on this page is copied from CMS's documents without rewording; whitespace is normalised, and one rendering artifact in CMS's HTML (a double quote standing in for an apostrophe) is corrected to the apostrophe in CMS's PDF report. This page is maintained by Logicly, which is not affiliated with CMS. Checked against the CMS files on 2026-10-16.