October 1 update. Our PDGM and ICD-10 tools now use the FY2027 code set: 190 codes added, 30 deleted, and no existing code changed clinical group.

See what changed
Lifetime rate: $24/mo

OASIS edit -7076: Inconsistent D0150G Items

Edit -7076 is a fatal consistency edit in CMS's OASIS-E2 data specifications V3.02.0, effective for records with completion dates on or after 2026-04-01. iQIES reports it as "Inconsistent D0150G Items". A fatal edit rejects the record: "Records with fatal errors will be rejected. All fatal errors in a record must be corrected and resubmitted." It checks 2 items: D0150G1, D0150G2. CMS's action: "Make appropriate corrections to the records and resubmit."

What CMS's data specification says about -7076

CMS's OASIS-E2 Data Submission Specifications V3.02.0 (HTML edit page oe_7076.html, generated 11/05/2025) list edit -7076 with edit type Consistency and severity Fatal. The edit text, as CMS publishes it:

(a) If D0150G1=[0], then D0150G2 must equal [0]. (b) If D0150G1=[1], then D0150G2 must equal [0,1,2,3,-]. (c) If D0150G1=[9,^,-], then D0150G2 must equal [^].

CMS's version note for -7076:

[V3.02.0]-New edit. Replaces edit -5870.

CMS's overview document defines this edit type: "Consistency edits define logical constraints among multiple items."

What the iQIES error message for -7076 says

CMS's OASIS Error Message Reference Guide v2.4 (Excel, posted 2026-02-05 on the QTSO reference manuals page) has 3 current entries for this edit. Each is copied in full, with whitespace normalised:

-7076a

Error ID
-7076a
Severity
Fatal
Type
Consistency
Error message
Inconsistent D0150G Items: If D0150G1 symptom presence is equal to no [0], then D0150G2 symptom frequency must equal never/1 day [0].
Potential cause
The value submitted in D0150G2 (Mood: Trouble concentrating) is not consistent with the value submitted in item D0150G1 (symptom frequency).
Tips
If D0150G1=[0], then D0150G2 must equal [0].
Action
Make appropriate corrections to the records and resubmit.
Effective start date
2026-04-01
Effective end date
2099-12-31 (CMS uses this date for an open-ended entry)

-7076b

Error ID
-7076b
Severity
Fatal
Type
Consistency
Error message
Inconsistent D0150G Items: If D0150G1 symptom presence is equal to yes [1], then D0150G2 symptom frequency must equal [0, 1, 2, 3, -].
Potential cause
The value submitted in D0150G2 (Mood: Trouble concentrating) is not consistent with the value submitted in item D0150G1 (symptom frequency).
Tips
If D0150G1=[1], then D0150G2 must equal [0,1,2,3,-].
Action
Make appropriate corrections to the records and resubmit.
Effective start date
2026-04-01
Effective end date
2099-12-31 (CMS uses this date for an open-ended entry)

-7076c

Error ID
-7076c
Severity
Fatal
Type
Consistency
Error message
Inconsistent D0150G Items: If D0150G1 symptom presence is equal to no response, skipped, or a dash [9, ^, -], then D0150G2 symptom frequency must equal skipped [^].
Potential cause
The value submitted in D0150G2 (Mood: Trouble concentrating) is not consistent with the value submitted in item D0150G1 (symptom frequency).
Tips
If D0150G1=[9,^,-], then D0150G2 must equal [^].
Action
Make appropriate corrections to the records and resubmit.
Effective start date
2026-04-01
Effective end date
2099-12-31 (CMS uses this date for an open-ended entry)

Items this edit checks

CMS's Item List for -7076 names 2 items.

Item IDDescription (CMS)Item page
D0150G1Mood: Trouble concentrating on things: PresD0150
D0150G2Mood: Trouble concentrating on things: FreqD0150

Other current edits whose CMS Item List shares one or more items with -7076 (the broad -3060 value edit, which covers 365 items, is left out):

Edit IDSeverityTypeiQIES labelItems shared
-7060FatalConsistencyInconsistent D0150 Items1
-7061FatalConsistencyInconsistent Item1

What happens to the record

CMS's overview, section 6.4, on fatal edits: "Violation of a fatal edit will result in rejection of the submission file." CMS's iQIES error message guide: "Records with fatal errors will be rejected. All fatal errors in a record must be corrected and resubmitted."

Which records this edit applies to

Data specifications version 3.02 has an effective start date of 2026-04-01 and no end date (CMS overview, Table 1). CMS selects the edit set by the record's completion date: "When a submitted record is validated by the iQIES system, its completion date is evaluated and is used to load the appropriate set of edits for the specifications in effect on that date."

Frequently asked questions

Is OASIS edit -7076 fatal or a warning?

Fatal. CMS lists edit -7076 with severity Fatal in the OASIS-E2 data specifications V3.02.0. The CMS overview states: "Violation of a fatal edit will result in rejection of the submission file." The iQIES error guide adds: "Records with fatal errors will be rejected. All fatal errors in a record must be corrected and resubmitted."

Which OASIS items can trigger edit -7076?

CMS's Item List for edit -7076 names 2 items: D0150G1, D0150G2. The full list with descriptions is in the table above.

How do I fix OASIS edit -7076?

CMS's OASIS Error Message Reference Guide v2.4 gives this action for -7076a: "Make appropriate corrections to the records and resubmit." Its tips: "If D0150G1=[0], then D0150G2 must equal [0]." The guide has 3 entries for this edit (-7076a, -7076b, -7076c); each is quoted above.

Which records does edit -7076 apply to?

Under version 3.02 of the data specifications, records whose completion date, item M0090_INFO_COMPLETED_DT, is on or after 2026-04-01, the effective start date CMS gives that version. Records completed earlier are checked under the version in effect on their completion date (CMS overview, Table 1 and section 3.2); the effective start date on each guide entry above is the date CMS's error guide gives that entry. The CMS overview states: "When a submitted record is validated by the iQIES system, its completion date is evaluated and is used to load the appropriate set of edits for the specifications in effect on that date."

What changed for edit -7076 in V3.02.0?

CMS's version note reads: "[V3.02.0]-New edit. Replaces edit -5870."

Sources

  1. CMS, OASIS-E2 Data Submission Specifications V3.02.0 FINAL (zip): HTML edit page oe_7076.html and the Unduplicated Edits By ID Report. https://www.cms.gov/files/zip/oasis-e2-data-specs-v3-02-0-final-zip.zip (download page: https://www.cms.gov/medicare/quality/home-health/data-specifications)
  2. CMS, OASIS Data Submission Specifications Overview, Version 3.02.0, October 29, 2025 (in the same zip).
  3. CMS QTSO, OASIS Error Message Reference Guide v2.4 (Excel), posted 2026-02-05. https://qtso.cms.gov/system/files/qtso/OASIS%20Error%20Message%20Reference%20Guide%20FINAL%202.4.26.xlsx

CMS text on this page is copied from CMS's documents without rewording; whitespace is normalised, and one rendering artifact in CMS's HTML (a double quote standing in for an apostrophe) is corrected to the apostrophe in CMS's PDF report. This page is maintained by Logicly, which is not affiliated with CMS. Checked against the CMS files on 2026-10-16.