OASIS edit -3090: Invalid Value
Edit -3090 is a fatal format edit in CMS's OASIS-E2 data specifications V3.02.0, effective for records with completion dates on or after 2026-04-01. iQIES reports it as "Invalid Value". A fatal edit rejects the record: "Records with fatal errors will be rejected. All fatal errors in a record must be corrected and resubmitted." It checks 17 items: CORRECTION_NUM, C0500, D0160, M1060_HEIGHT_A, M1060_WEIGHT_B, M1311_NBR_PRSULC_STG2_A1, and more. CMS's action: "Make appropriate corrections to the record and resubmit."
What CMS's data specification says about -3090
CMS's OASIS-E2 Data Submission Specifications V3.02.0 (HTML edit page oe_3090.html, generated 11/05/2025) list edit -3090 with edit type Format and severity Fatal. The edit text, as CMS publishes it:
VALUES OF NUMERIC ITEMS Only the values listed in the "Item Values" table of the Detailed Data Specifications Report may be submitted for this item. The submitted value must be greater than or equal to the minimum value listed in the table and less than or equal to the maximum value listed in the table, or it must match one of the remaining special values (if any) that are listed in the table. The length of the submitted value must not exceed the allowed maximum length for the item. Signed numbers (with a leading plus or minus sign) will not be accepted.
CMS's overview document defines this edit type: "Format edits specify special rules for formatting item values."
What the iQIES error message for -3090 says
CMS's OASIS Error Message Reference Guide v2.4 (Excel, posted 2026-02-05 on the QTSO reference manuals page) has 1 current entry for this edit. Each is copied in full, with whitespace normalised:
-3090
- Error ID
- -3090
- Severity
- Fatal
- Type
- Format
- Error message
- Invalid Value: Only numeric values that are within the range of acceptable values and specified special characters are valid for this item.
- Potential cause
- The value submitted in this item is invalid; it is not one of the numeric values or special characters allowed.
- Tips
- • An unsigned numeric value is a number without a leading plus or minus sign.• Negative (signed) numbers are not allowed.
- Action
- Make appropriate corrections to the record and resubmit.
- Effective start date
- 2010-01-01
- Effective end date
- 2099-12-31 (CMS uses this date for an open-ended entry)
Items this edit checks
CMS's Item List for -3090 names 17 items.
| Item ID | Description (CMS) | Item page |
|---|---|---|
| CORRECTION_NUM | Correction number | none yet |
| C0500 | BIMS Summary Score | C0500 |
| D0160 | Total severity score | D0160 |
| M1060_HEIGHT_A | Height (in inches) | none yet |
| M1060_WEIGHT_B | Weight (in pounds) | none yet |
| M1311_NBR_PRSULC_STG2_A1 | Number of Stage 2 Pressure Ulcers | M1311 |
| M1311_NBR_ULC_SOCROC_STG2_A2 | Number of Stage 2 pressure ulcers at SOC/ROC | M1311 |
| M1311_NBR_PRSULC_STG3_B1 | Number of Stage 3 Pressure Ulcers | M1311 |
| M1311_NBR_ULC_SOCROC_STG3_B2 | Number of Stage 3 pressure ulcers at SOC/ROC | M1311 |
| M1311_NBR_PRSULC_STG4_C1 | Number of Stage 4 Pressure Ulcers | M1311 |
| M1311_NBR_ULC_SOCROC_STG4_C2 | Number of Stage 4 pressure ulcers at SOC/ROC | M1311 |
| M1311_NSTG_DRSG_D1 | Num unstage pressure ulcer non-remov dress | M1311 |
| M1311_NSTG_DRSG_SOCROC_D2 | Num unstage pressure ulcer non-remov dress SOC/ROC | M1311 |
| M1311_NSTG_CVRG_E1 | Unstageable: coverage by slough or eschar | M1311 |
| M1311_NSTG_CVRG_SOCROC_E2 | Unstageable: coverage by slough or eschar SOC/ROC | M1311 |
| M1311_NSTG_DEEP_TSUE_F1 | Unstageable: deep tissue injury | M1311 |
| M1311_NSTG_DEEP_TSUE_SOCROC_F2 | Unstageable: deep tissue injury SOC/ROC | M1311 |
Related edits
Other current edits whose CMS Item List shares one or more items with -3090:
| Edit ID | Severity | Type | iQIES label | Items shared |
|---|---|---|---|---|
| -3100 | Fatal | Format | Invalid Numeric Format | 17 |
| -5112 | Fatal | Skip pattern | No label in the guide | 12 |
| -5123 | Fatal | Skip pattern | No label in the guide | 6 |
| -5132 | Fatal | Consistency | No label in the guide | 6 |
| -5661 | Fatal | Consistency | No label in the guide | 6 |
| -5681 | Fatal | Consistency | No label in the guide | 3 |
| -5371 | Fatal | Skip pattern | Invalid Skip Pattern / Inconsistent M1311 Values | 2 |
| -5372 | Fatal | Consistency | Inconsistent M1311 Values | 2 |
What happens to the record
CMS's overview, section 6.4, on fatal edits: "Violation of a fatal edit will result in rejection of the submission file." CMS's iQIES error message guide: "Records with fatal errors will be rejected. All fatal errors in a record must be corrected and resubmitted."
Which records this edit applies to
Data specifications version 3.02 has an effective start date of 2026-04-01 and no end date (CMS overview, Table 1). CMS selects the edit set by the record's completion date: "When a submitted record is validated by the iQIES system, its completion date is evaluated and is used to load the appropriate set of edits for the specifications in effect on that date."
Frequently asked questions
Is OASIS edit -3090 fatal or a warning?
Fatal. CMS lists edit -3090 with severity Fatal in the OASIS-E2 data specifications V3.02.0. The CMS overview states: "Violation of a fatal edit will result in rejection of the submission file." The iQIES error guide adds: "Records with fatal errors will be rejected. All fatal errors in a record must be corrected and resubmitted."
Which OASIS items can trigger edit -3090?
CMS's Item List for edit -3090 names 17 items: CORRECTION_NUM, C0500, D0160, M1060_HEIGHT_A, M1060_WEIGHT_B, M1311_NBR_PRSULC_STG2_A1, M1311_NBR_ULC_SOCROC_STG2_A2, M1311_NBR_PRSULC_STG3_B1, M1311_NBR_ULC_SOCROC_STG3_B2, M1311_NBR_PRSULC_STG4_C1, M1311_NBR_ULC_SOCROC_STG4_C2, M1311_NSTG_DRSG_D1, and 5 more. The full list with descriptions is in the table above.
How do I fix OASIS edit -3090?
CMS's OASIS Error Message Reference Guide v2.4 gives this action for -3090: "Make appropriate corrections to the record and resubmit." Its tips: "• An unsigned numeric value is a number without a leading plus or minus sign. • Negative (signed) numbers are not allowed."
Which records does edit -3090 apply to?
Under version 3.02 of the data specifications, records whose completion date, item M0090_INFO_COMPLETED_DT, is on or after 2026-04-01, the effective start date CMS gives that version. Records completed earlier are checked under the version in effect on their completion date (CMS overview, Table 1 and section 3.2); the effective start date on each guide entry above is the date CMS's error guide gives that entry. The CMS overview states: "When a submitted record is validated by the iQIES system, its completion date is evaluated and is used to load the appropriate set of edits for the specifications in effect on that date."
Sources
- CMS, OASIS-E2 Data Submission Specifications V3.02.0 FINAL (zip): HTML edit page
oe_3090.htmland the Unduplicated Edits By ID Report. https://www.cms.gov/files/zip/oasis-e2-data-specs-v3-02-0-final-zip.zip (download page: https://www.cms.gov/medicare/quality/home-health/data-specifications) - CMS, OASIS Data Submission Specifications Overview, Version 3.02.0, October 29, 2025 (in the same zip).
- CMS QTSO, OASIS Error Message Reference Guide v2.4 (Excel), posted 2026-02-05. https://qtso.cms.gov/system/files/qtso/OASIS%20Error%20Message%20Reference%20Guide%20FINAL%202.4.26.xlsx
CMS text on this page is copied from CMS's documents without rewording; whitespace is normalised, and one rendering artifact in CMS's HTML (a double quote standing in for an apostrophe) is corrected to the apostrophe in CMS's PDF report. This page is maintained by Logicly, which is not affiliated with CMS. Checked against the CMS files on 2026-10-16.