October 1 update. Our PDGM and ICD-10 tools now use the FY2027 code set: 190 codes added, 30 deleted, and no existing code changed clinical group.

See what changed
Lifetime rate: $24/mo

OASIS edit -3220: Inconsistent Software Information

Edit -3220 is a fatal consistency edit in CMS's OASIS-E2 data specifications V3.02.0, effective for records with completion dates on or after 2026-04-01. iQIES reports it as "Inconsistent Software Information". A fatal edit rejects the record: "Records with fatal errors will be rejected. All fatal errors in a record must be corrected and resubmitted." It checks 2 items: SFW_PROD_NAME, SFW_PROD_VRSN_CD. CMS's action: "Make appropriate corrections to the records and resubmit."

What CMS's data specification says about -3220

CMS's OASIS-E2 Data Submission Specifications V3.02.0 (HTML edit page oe_3220.html, generated 11/05/2025) list edit -3220 with edit type Consistency and severity Fatal. The edit text, as CMS publishes it:

If SFW_PROD_NAME is equal to [^], then SFW_PROD_VRSN_CD must be equal to [^].

CMS's overview document defines this edit type: "Consistency edits define logical constraints among multiple items."

What the iQIES error message for -3220 says

CMS's OASIS Error Message Reference Guide v2.4 (Excel, posted 2026-02-05 on the QTSO reference manuals page) has 1 current entry for this edit. Each is copied in full, with whitespace normalised:

-3220

Error ID
-3220
Severity
Fatal
Type
Consistency
Error message
Inconsistent Software Information: If SFW_PROD_NAME equals blank (^), then SFW_PROD_VRSN_CD must equal blank (^).
Potential cause
The value submitted in SFW_PROD_VRSN_CD (Software Product Version Code) is not consistent with the value submitted in SFW_PROD_NAME (Software Product Name).
Tips
IF SFW_PROD_NAME is blank (^), THEN SFW_PROD_VRSN_CD must be blank (^).
Action
Make appropriate corrections to the records and resubmit.
Effective start date
2010-01-01
Effective end date
2099-12-31 (CMS uses this date for an open-ended entry)

Items this edit checks

CMS's Item List for -3220 names 2 items.

Item IDDescription (CMS)Item page
SFW_PROD_NAMESoftware product namenone yet
SFW_PROD_VRSN_CDSoftware product version codenone yet

Other current edits whose CMS Item List shares one or more items with -3220:

Edit IDSeverityTypeiQIES labelItems shared
-3210FatalFormatInvalid Format2
-3230FatalConsistencyInconsistent Software Vendor Information2
-3130FatalFormatInvalid Format1
-3250FatalFormatInvalid Format1

What happens to the record

CMS's overview, section 6.4, on fatal edits: "Violation of a fatal edit will result in rejection of the submission file." CMS's iQIES error message guide: "Records with fatal errors will be rejected. All fatal errors in a record must be corrected and resubmitted."

Which records this edit applies to

Data specifications version 3.02 has an effective start date of 2026-04-01 and no end date (CMS overview, Table 1). CMS selects the edit set by the record's completion date: "When a submitted record is validated by the iQIES system, its completion date is evaluated and is used to load the appropriate set of edits for the specifications in effect on that date."

Frequently asked questions

Is OASIS edit -3220 fatal or a warning?

Fatal. CMS lists edit -3220 with severity Fatal in the OASIS-E2 data specifications V3.02.0. The CMS overview states: "Violation of a fatal edit will result in rejection of the submission file." The iQIES error guide adds: "Records with fatal errors will be rejected. All fatal errors in a record must be corrected and resubmitted."

Which OASIS items can trigger edit -3220?

CMS's Item List for edit -3220 names 2 items: SFW_PROD_NAME, SFW_PROD_VRSN_CD. The full list with descriptions is in the table above.

How do I fix OASIS edit -3220?

CMS's OASIS Error Message Reference Guide v2.4 gives this action for -3220: "Make appropriate corrections to the records and resubmit." Its tips: "IF SFW_PROD_NAME is blank (^), THEN SFW_PROD_VRSN_CD must be blank (^)."

Which records does edit -3220 apply to?

Under version 3.02 of the data specifications, records whose completion date, item M0090_INFO_COMPLETED_DT, is on or after 2026-04-01, the effective start date CMS gives that version. Records completed earlier are checked under the version in effect on their completion date (CMS overview, Table 1 and section 3.2); the effective start date on each guide entry above is the date CMS's error guide gives that entry. The CMS overview states: "When a submitted record is validated by the iQIES system, its completion date is evaluated and is used to load the appropriate set of edits for the specifications in effect on that date."

Sources

  1. CMS, OASIS-E2 Data Submission Specifications V3.02.0 FINAL (zip): HTML edit page oe_3220.html and the Unduplicated Edits By ID Report. https://www.cms.gov/files/zip/oasis-e2-data-specs-v3-02-0-final-zip.zip (download page: https://www.cms.gov/medicare/quality/home-health/data-specifications)
  2. CMS, OASIS Data Submission Specifications Overview, Version 3.02.0, October 29, 2025 (in the same zip).
  3. CMS QTSO, OASIS Error Message Reference Guide v2.4 (Excel), posted 2026-02-05. https://qtso.cms.gov/system/files/qtso/OASIS%20Error%20Message%20Reference%20Guide%20FINAL%202.4.26.xlsx

CMS text on this page is copied from CMS's documents without rewording; whitespace is normalised, and one rendering artifact in CMS's HTML (a double quote standing in for an apostrophe) is corrected to the apostrophe in CMS's PDF report. This page is maintained by Logicly, which is not affiliated with CMS. Checked against the CMS files on 2026-10-16.